Rent Anritsu Site Master S331A Cable & Antenna Analyzer

Details

Features

Accurate Test of Antenna Systems and Active/Passive Components
Built-in Distance-To-Fault
Immunity to Live Site RF Interference
Synthesizer Accurate to 75 ppm
Trace Storage, 40 Max.
Automatically date/ time stamp
Alphanumeric labeling give distinct names
Instrument calibration is valid in all data point setting
10 user configurations include calibrations
Silica Glass Based Optical Fibers
Math Functions: Trace – Memory, Trace + Memory
Direct Printer Control via RS232 Serial Port

Rent Site Master S331A

The Site Master S331A is a hand held SWR/RL (standing wave ratio/return loss), and Distance-To- Fault (DTF) measurement instrument that includes a built-in synthesized signal source. All models include a keypad to enter data and a liquid crystal display (LCD) to provide graphic indications of SWR or RL over the selected frequency range and selected distance.

The Site Master is designed for measuring SWR, return loss, or cable insertion loss and locating faulty RF components in antenna systems. Power monitoring is available as an option. The displayed trace can be scaled or enhanced with frequency markers or a limit line. A menu option provides for an audible “beep” when the limit value is exceeded. To permit use in low-light environments, the LCD can be back lit using a front panel key.

The Site Master Software Tools program also performs DTF (Distance To Fault) and Fault Location.

Rent Anritsu Site Master S331A

Specifications:

Frequency Range: 25 to 3300 MHz
Frequency Accuracy: (RF Source Mode) 75 parts per million @ 25°C*
Frequency Resolution: 100 kHz
SWR:

  • Range: 1.00 to 65.00
  • Resolution: 0.01Return Loss:
  • Range: 0.00 to 54.00 dB
  • Resolution: 0.01 dbTest Port, Type N 50 Ohms ***Immunity to Interfering signals up to the level of: –5 dBm, reflection
    Maximum Input (Damage Level):
  • Test Port, Type N: +22 dBmRF Detector: +20 dBm|
    Measurement Accuracy:
  • Measurement accuracy depends on calibration components. Precision calibration components have a directivity of 42 dB.Cable Insertion Loss:
  • Range: 0.00 to 54.00 dB
  • Resolution: 0.01 dBFrequency Reference
  • Aging: ±1 ppm/yr
  • Accuracy: ±2 ppmInternal Memory:
  • Trace Memory: 40 maximumInstrument config.:
  • 10 setup locations
  • RS-232: 9 pin D-sub, three wire serial
  • Electromagnetic Compatibility Meets European community requirements for CE markingPower Supply:
  • External DC Input: +11 to +15 Vdc, 1250 mA max.Temperature:
  • Storage: –20° C to 75° C
  • Operation: 0° C to 50° C

Lease Anritsu Site Master S331A Cable & Antenna Analyzer Rental